Home Inspection Report Resources and Reference Documents

Your SafeSpec inspection report may link to this page of home inspection report resources: the manufacturer instructions, industry guides and government publications behind a recommendation. Each section below links directly to the official source so you, your agent or your contractor can read the original document.

Planning ahead for repairs and replacements? See the InterNACHI estimated life expectancy chart for homes. To learn what a full inspection covers, visit our St. Louis home inspection page.

Fiber Cement Siding (James Hardie Installation Instructions)

Fiber cement siding must be installed to the manufacturer’s instructions to perform well and keep its warranty.

Common issues include missing clearance to the roof, ground, decks and flashing, missing kickout flashing, improper nailing, unsealed cut ends, and butt joints without flashing. James Hardie publishes installation instructions and best practice guides for each product line.

EIFS and Stucco

EIFS (exterior insulation and finish system, sometimes called synthetic stucco) and traditional cement stucco both depend on proper flashing, sealant joints and drainage to keep water out of the wall.

Damage behind the finish is often hidden, which is why a specialized EIFS or stucco inspection, which may include moisture probing, is recommended when concerns are found.

Decks (DCA 6 Deck Construction Guide)

The American Wood Council’s DCA 6 is the most widely used prescriptive guide for building a wood deck. Inspectors use it as a reference for ledger attachment, flashing, joist hangers, beam and post connections, footings, guards and stairs.

Many deck failures happen at the ledger board where the deck attaches to the house.

Electrical Panels: Shared Neutral Terminals

In an electrical panel, each neutral (white) wire should have its own terminal on the neutral bar. NEC 408.41 requires each grounded (neutral) conductor to terminate in an individual terminal not used for another conductor.

The reason is safety during service: if two neutrals share a screw and one is removed, the other can come loose too. On a shared (multiwire) circuit, a loose neutral can send excessive voltage to lights and appliances.

This rule does not apply the same way to bare or green ground wires; whether ground wires can share a terminal depends on the panel manufacturer’s label inside the panel door. A qualified electrical contractor can move doubled neutrals to their own terminals.

For other electrical findings, see our guide to ungrounded outlets, open grounds and bootleg grounds.

Radon (EPA and Missouri Radon Guides)

Radon is a radioactive gas from soil that can build up in homes. According to the EPA, it is the second leading cause of lung cancer in the United States. The only way to know your level is to test.

The EPA recommends fixing a home at 4 pCi/L or higher. The Missouri Department of Health and Senior Services reports that about 1 in 3 Missouri homes tested were above that level, and offers free short-term test kits to Missouri residents while supplies last.

Buying a home? SafeSpec offers radon testing in St. Louis.

Frequently Asked Questions About Home Inspection Report Resources

Why does my home inspection report link to reference documents?

The links point to the manufacturer instructions, industry guides and government publications behind a recommendation in your report. Each one goes directly to the official source so you, your agent or your contractor can read the original document.

Where can I find James Hardie siding installation instructions?

James Hardie publishes installation instructions and best practice guides for each product line in its online technical document library. Fiber cement siding must be installed to the manufacturer’s instructions to perform well and keep its warranty.

What is the DCA 6 deck guide?

DCA 6 is the American Wood Council’s prescriptive guide for building a wood deck, and it is the most widely used guide of its kind. Inspectors use it as a reference for ledger attachment, flashing, joist hangers, beam and post connections, footings, guards and stairs.

Can two neutral wires share one terminal in an electrical panel?

No. NEC 408.41 requires each grounded (neutral) conductor to terminate in an individual terminal not used for another conductor. If two neutrals share a screw and one is removed, the other can come loose too. A qualified electrical contractor can move doubled neutrals to their own terminals.

What radon level should be fixed?

The EPA recommends fixing a home at 4 pCi/L or higher. The Missouri Department of Health and Senior Services reports that about 1 in 3 Missouri homes tested were above that level. The only way to know your level is to test.

Buying a home or have questions about any of these documents or your report? Schedule your inspection with SafeSpec, call SafeSpec Home Inspections at (314) 375-6014 or email Inspector@SafeSpec.net. We serve St. Louis City and County, St. Charles County and Jefferson County.

Sources

All documents listed above link to the publishing manufacturer, industry association or government agency. Links were checked in October 2026; if a link moves, search the publisher’s site for the document title.